As the core power source of the cooling system, the lifespan of the cooling tower motor directly affects the stability of industrial production and cost control. To ensure the long-term efficient operation of motors, it is necessary to establish a scientific management system from multiple dimensions such as installation standards, daily maintenance, and environmental management. The following are the key methods that have been verified through practice.

Precise installation is the cornerstone of lifespan. When installing the motor, the levelness must be strictly controlled. The error between the base and the foundation should be controlled within 0.1mm/m to avoid premature wear of the bearings due to uneven force. When connecting transmission components, the coaxiality deviation of the coupling should be less than 0.05mm. For belt drives, it is necessary to ensure uniform tension. If it is too loose, it is prone to slippage and heat generation; if it is too tight, it will increase the load on the shaft system. Meanwhile, the cable terminal blocks need to be coated with antioxidant, and the sealing of the junction box should reach the IP54 protection level to prevent short-circuit faults caused by damp environments.


电机内页英文_13



Scientific maintenance reduces the risk of failure. Regular lubrication is the core to extending the service life of bearings. The appropriate grease should be selected based on the ambient temperature: lithium-based grease should be used when the ambient temperature is above 40℃, and silicon-based grease should be used when it is below 0℃. Each time, the amount of grease added should fill two-thirds of the bearing cavity. Excessive addition will lead to poor heat dissipation. The insulation resistance of the liangchi cooling tower motor winding should be checked monthly using a 500V megohmmeter. When the value is lower than 0.5MΩ, it needs to be dried in time. In addition, the accumulated dust between the fan blades and the casing should be cleaned every quarter to ensure that the ventilation volume meets the heat dissipation requirements. Especially in dusty environments such as textile and chemical industries, the cleaning cycle should be shortened to once a month.

Environmental control reduces hidden losses. Water deflectors should be set up around the cooling tower to prevent the spray water from directly splashing onto the motor surface. The outer shell should be regularly coated with anti-corrosion paint. In coastal areas, it is recommended to use a protective shell made of 316 stainless steel. When the temperature is high in summer, an axial flow fan can be installed near the motor to force cooling, ensuring that the operating environment temperature does not exceed 40℃. In cold regions during winter, proper insulation measures should be taken to prevent the viscosity of the lubricating oil from increasing, which could lead to excessive starting load. For places with large voltage fluctuations, voltage stabilizers should be equipped to keep the voltage deviation within ±5% and reduce the risk of winding overheating.

18165548m0i9

Status monitoring enables proactive maintenance. It is recommended to install vibration sensors and temperature monitoring modules to monitor the motor operation parameters in real time: during normal operation, the vibration velocity should be less than 2.8mm/s, and the bearing temperature should not exceed 95℃. Establish an equipment operation ledger, recording the time of each maintenance, the model of replaced parts and the cause of faults, and predict potential problems through data analysis. When the motor makes abnormal noises or the current fluctuation exceeds 10%, it should be stopped immediately for inspection to prevent minor faults from expanding into irreversible damage.

Extending the lifespan of cooling tower motors is a systematic project, which requires not only standardized operation procedures but also relies on meticulous management awareness. By integrating the above measures into the daily operation and maintenance system, not only can the average lifespan of motors be extended from 5 years to over 8 years, but also the production losses caused by unplanned shutdowns can be significantly reduced, creating continuous and stable economic benefits for the enterprise.


Contact us

Consult Your Mach Cooling Tower Experts

We help you avoid the pitfalls to deliver the quality and value your window opener need, on-time and on-budget.

Download Technical Catalog

If you want to know detailed information,please download catalogue here.
Contact Us
   +86-13735399597
  Lingjiang Village, Dongguan Street, Shangyu District, Shaoxing City, Zhejiang Province, China.
Industrial Cooling Tower
Closed Cooling Tower
Open Cooling Tower
Links
COPYRIGHT © 2025 ZHEJIANG AOSHUAI REFRIGERATION CO., LTD. ALL RIGHTS RESERVED.